VP-EC-DCIM-BCM Gateway

Branch Current Monitor Gateway

Responsive image

The VP-EC-DCIM-BCM is a complete breaker panel branch current monitoring system. Up to 2 VP-EC-BCM-42CT Interfaces can be connected for a total of 84 breakers. Each interface transmits its current readings to the gateway via Modbus RTU RS485 protocol. The VP-EC-BCM-Gateway's built in web server allows the user to program all alarm and operating settings for the breaker variables. Email alerts are programmed for Warning, High, and Zero Load Alarm.

Standard Features of the VP-EC-DCIM-BCM Gateway:

Block Diagram

Responsive image Back to Top

Specifications

Item Metric Value
I/O Part Name : Environment Monitoring Gateway
Part Number : VP-EC-DCIM Gateway
Ethernet Protocol : 10/100 Base T RJ45 Connector (EnviroCloud connection)
MODBUS over TCP/IP
Breaker Port 1 Strip A Protocol : Modbus RTU RS485
VP-EC-BCM-42CT Interface Port
Used for breaker panels up to 42 Breakers
Baud Rate Default 19200 (N81)
Termination Jumper Selectable Enable or Disable 120 Ohm Resistor
Wiring 1 RJ45 Jacks, Power over Cat5e Cable
Breaker Port 2 Strip B Protocol : Modbus RTU RS485
VP-EC-BCM-42CT Interface Port
Used for breaker panels up to 84 Breakers
Baud Rate Default 19200 (N81)
Termination Jumper Selectable Enable or Disable 120 Ohm Resistor
Wiring 1 RJ45 Jacks, Power over Cat5e Cable
Local Modbus Protocol : Modbus RTU RS485
VP-TX-DCIM Environment Hub Connection Port
Baud Rate Default 19200 (N81)
Termination Jumper Selectable Enable or Disable 120 Ohm Resistor
Wiring 2 sets of RJ45 Jacks, Power over Cat5e Cable
Remote Modbus Protocol : Modbus RTU RS485
Connection Port for remote access to all environment data
Baud Rate Default 19200 (N81)
Termination Jumper Selectable Enable or Disable 120 Ohm Resistor
Wiring 2 sets of RJ45 Jacks, Power over Cat5e Cable
Display Port Protocol : Modbus RTU RS485
Remote User Interface (RDU Display) Port
Baud Rate Default 19200 (N81)
Termination Jumper Selectable Enable or Disable 120 Ohm Resistor
Wiring 1 sets of RJ45 Jacks, Power over Cat5e Cable
Processor Processor : ARM
Status LEDs Power ON LED : Blue LED Indicator (Always ON)
Status LEDs (2) : GREEN for Status OK
AMBER for CAUTION Alarm
RED for CRITICAL Alarm
User Interface Character LCD : 2 Line x 16 Charater (White on Blue)
4 Pushbuttons : MENU, UP, DOWN, WENTER
Audible : Internal Audible (75 db)
Programmable On or Off
Physical Length : 6.25"
Width : 3.6"
Depth : 2.3"
Weight : 200 g
Weight, Shipping (Qty. 1) : 300 g
Material : ABS, UL94-5VA
Mounting : DIN rail mounting
Electrical Power Input Voltage Range (Typical) : 24 VDC
Power Input (Minimum) : 10 VDC
Power Input (Maximum) : 28 VDC
Current max : 100 mA
Current typical : 125 mA
Ambient Operating Temperature : -20 to +65 °C
Storage Temperature : -20 to +65 °C
Operating Relative Humidity (non-condensing) : 5 to 95 %RH )
Storage Relative Humidity (non-condensing) : 0 to 95 %RH
Warranty Limited Liability : Product Replacement 1 Year
Download : Warranty Statement